Datenbeschreibungen
9.6 Nahtstellensignale
DB18
Signal
FRDP[1..3].ACK_REI
FRDP_HF[4..16].ACK_R
EI
Ausgänge
FRDP[1..3].ERROR
FRDP_HF[4..16].ER‐
ROR
FRDP[1..3].SUBS_ON
FRDP_HF[4..16].SUBS_
ON
FRDP[1..3].ACK_REQ
FRDP_HF[4..16].ACK_R
EQ
FRDP[1..3].SENDMO‐
DE
FRDP_HF[4..16].SEND‐
MODE
FRDP[..3].DIAG
FRDP_HF[4..16].DIAG
FRDP[1..3].RETVAL14
FRDP_HF[4..16].RET‐
VAL14
FRDP[1..3].RETVAL15
FRDP_HF[4..16].RET‐
VAL15
User Data
MD13312: $MN_SAFE_SPL_USER_DATA[0]=1h entspricht DB18.DBX259.0 = 1
MD13312: $MN_SAFE_SPL_USER_DATA[1]=2702h entspricht
DB18.DBX263.1 = 1
DB18.DBX262.0 = 1
DB18.DBX262.1 = 1
DB18.DBX262.2 = 1
DB18.DBX262.5 = 1
Datenbereich/Status
SPL_DATA_HF.IN‐
SEP[65...192]
SPL_DATA_HF.OUT‐
SEP[ 65...192]
516
r/w
Typ
Wertebereich
r/w
Bool
TRUE/FALSE
r
Bool
TRUE/FALSE
r
Bool
TRUE/FALSE
r
Bool
TRUE/FALSE
r
Bool
TRUE/FALSE
r
Word
2#0000_0000_
0000_0000
-
2#1110_0000_0
111_0000
r
Word
r
Word
r
Bool
r/w
Bool
Bemerkung
1 = Anwenderquittierung
0 = Normalbetrieb
1 = Kommunikationsfehler
0 = Ausgabe von Prozesswerten
1 = Ausgabe von Ersatzwerten
1 = Anwenderquittierung erforderlich
1 = F_CPU des Senders im deaktivierten Sicherheitsbetrieb
Bit 0-3: reserviert
Bit 4: 1 = Timeout erkannt
Bit 5: 1 = Sequenznummernfehler erkannt
Bit 6: 1 = CRC-Fehler erkannt
Bit 7-12: reserviert
Bit 13: 1 = Abweichungen in den F-Telegrammdaten (Tele‐
gram Discrepancy)
Bit 14: 1 = Lebenszeichenüberwachung (LifeSign)
Bit 15: 1 = Asynchroner Fehlerzustand (StateFault)
Fehlercode des SFC 14 (Beschreibung der Fehlercodes in
der Onlinehilfe zum SFC 14)
Fehlercode des SFC 15 (Beschreibung der Fehlercodes in
der Onlinehilfe zum SFC 15)
externer PLC-Eingang für SPL Nutzdaten
externer PLC-Eingang für SPL Nutzdaten
Funktionshandbuch, 12/2017, 6FC5397-4BP40-6AA1