AKD Benutzerhandbuch | 25.17.32 FB1.RESKTR
25.17.32 FB1.RESKTR
General Information
Type
Description
Units
Range
Default Value 0.5
Data Type
Float
See Also
Start Version M_01-00-00-000
Variants Supported
Variant
AKD Base
AKD with Position Indexer
AKD EtherCAT
AKD CANopen
AKD BASIC
AKD SynqNet
AKD EtherNet/IP
AKD Profinet
AKD sercos ® III
AKD-N
AKD-C
Fieldbus Information
Fieldbus
Address Attributes Signed?
Profinet
2153
sercos ® III
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus
306
Description
This parameter sets the resolver nominal transformation ratio. It affects the resolver excitation output
amplitude.
The value can be obtained from the resolver data sheet.
Related Topics
Rückführung 1 (➜ S. 75)
NV Parameter
Sets the resolver nominal transformation
ratio.
N/A
0.001 to 50.000
N/A
Supported
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Word
No
2 Octets
No
16 bit
No
M_01-03-00-000
No
KOLLMORGEN | Dezember 2014
777