AKD Benutzerhandbuch | 25.29.36 MOTOR.VMAX

25.29.36 MOTOR.VMAX

General Information
Type
Description
Units
Range
Default Value 3,000 rpm
Data Type
Start Version M_01-00-00-000
Variants Supported
Variant
AKD Base
AKD with Position Indexer
AKD EtherCAT
AKD CANopen
AKD BASIC
AKD SynqNet
AKD EtherNet/IP
AKD Profinet
AKD sercos ® III
AKD-N
AKD-C
Fieldbus Information
Fieldbus
EtherCAT COE and CANopen 35A3h/0
Fieldbus
Address Attributes Signed?
Profinet
2261
sercos ® III
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus
522
Description
This parameter sets the maximum motor mechanical speed. The value 1.2 x MOTOR.VMAX beco-
mes the overall overspeed fault threshold (VL.VFTHRESH) if it is less than the user overspeed fault
threshold (VL.THRESH), and for MOTOR.TYPE = 6 if it is less than the motor back EMF overspeed
threshold ((1.02 x 1000 x VBUS.OVFTHRESH) / (MOTOR.KE x sqrt(2))).
Related Topics
NV Parameter
Sets the maximum motor speed.
rpm
100 to 40,000 rpm
Integer
Supported
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Index/Subindex Object Start Version
Word
No
2 Octets
No
16 bit
No
M_01-00-00-000
M_01-03-00-000
No
KOLLMORGEN | Dezember 2014