Parameterization and Configuration

6.4.2.4 Output data

6.4.2.4.1 Preset adjustment / Magnet number
Adjustment / Magnet number
Byte
X+0
Bit
31 – 24
31
Data
2
– 2
Bit
Description
Magnet Number
0...15
for which the preset adjustment will be executed or deleted (binary coded)
16...29
reserved
Delete adjustment value
With a rising edge 0->1 of this bit, the calculated zero point correction is deleted
30
(difference between desired preset value and physical measuring system position). After
deletion of the zero point correction, the measuring system outputs its "real" physical
position.
Set adjustment value
31
With a rising edge 0->1 of this bit, the current position value for the selected "magnet
number" is set to the value defined in "preset adjustment value".
6.4.2.4.2 Adjustment value
Adjustment value, relating to the addressed magnet or magnets (Integer32)
Byte
X+4
Bit
31 – 24
31
Data
2
– 2
 TR-Electronic GmbH 2018, All Rights Reserved
Page 154 of 167
Danger of physical injury and damage to property due to an actual value
jump during execution of the preset adjustment function!
• The preset adjustment function should only be executed when the
measuring system is stationary, or the resulting actual value jump must be
permitted by both the program and the application!
X+1
23 – 16
24
23
2
– 2
X+5
23 – 16
24
23
2
– 2
TR - ELA - BA - DGB - 0030 - 02
X+2
15 – 8
16
15
2
– 2
X+6
15 – 8
16
15
2
– 2
X+3
7 – 0
8
7
0
2
– 2
X+7
7 – 0
8
7
0
2
– 2
Printed in the Federal Republic of Germany