Parameterization and Configuration
6.3.3.19 Preset value
Alternatively, this parameter can also be set during operation via acyclic parameter access to the
preset value function PNU 65000, see 129.
The zero point of the measuring system can be adapted to the mechanical zero point via the Preset
value parameter and is set either as an absolute value or as a relative value, in relation to the
position output, during execution of the preset function, see chapter "Preset function" on page 141.
Data type
Integer32, two's complement
31
Lower limit
-2
31
Upper limit
+2
Default
0
 TR-Electronic GmbH 2018, All Rights Reserved
Page 124 of 167
–1
TR - ELA - BA - DGB - 0030 - 02
Printed in the Federal Republic of Germany
08/06/2019