Parameterization and Configuration
6.3.3.1 TR Encoder parametrization
Selection
Value Description
disable
enable
6.3.3.2 Interpolation
The interpolation is not supported. For this parameter, "0" is output in the corresponding byte in the
data stream.
6.3.3.3 Observer
The observer function is not supported. For this parameter, "0" is output in the corresponding byte in
the data stream.
6.3.3.4 Averaging
With this parameter the output position value can be averaged and the output jitter can thus be
minimized.
Lower limit
0
Upper limit
32
Default
0
0, 1: No averaging
2:
averaging of 2 values
...
32:
averaging of 32 values
 TR-Electronic GmbH 2018, All Rights Reserved
Page 118 of 167
Manufacturer-specific parameters
0
Interpolation, observer and averaging are disabled.
Manufacturer-specific parameters
1
Interpolation, observer and averaging are enabled.