Parameterization and Configuration
6.4 TR Encoder Profile
6.4.1 Configurable module parameters
The parameters can be set according to the following table via an input mask in the configuration tool
and are automatically sent by the control to the measuring system during start-up via the record data
object with index 0x0001.
Byte
Parameter
0
Interpolation
1
Code Sequence
Scaling:
2-5
Measuring step
[nm]
Number of
6
magnets
7
Observer
8
Averaging
9-12
Unit v [0.01mm/s]
13
Handling error
14-15
Option 1
16-19
Option 2
 TR-Electronic GmbH 2018, All Rights Reserved
Page 144 of 167
Data type
Description
Parameter is not supported
Unsigned8
Code sequence, in relation to the bar end
Unsigned8
0: Rising
1: Decreasing
The resolution is measured in nm/increment
1000:
2000:
5000:
Unsigned32
10 000:
50 000: 50 µm
100 000:
1000 000: 1 mm
Specification of configured magnets
0: Specification of submodules
1: 1 magnet
Unsigned8
2: 2 magnets
3: 3 magnets
. . .
30: 30 magnets
Unsigned8
Parameter is not supported
Averaging of position values
0...32
Unsigned8
Default value: 0, no averaging
Parameter is not supported
Unsigned32
PROFINET diagnostic alarm ON/OFF
0: Alarm only in process data (status)
Unsigned8
1: Send alarm and process data
(status)
Unsigned16
reserved
Unsigned32
reserved