Herunterladen Inhalt Inhalt Diese Seite drucken

SICK S3000 Expert Bedienungsanleitung Seite 97

Sicherheits-laserscanner
Inhaltsverzeichnis

Werbung

Telegram Listing CMS
S3000/S300 Expert
Block description
Data block name
Config master block
8015791/WS20/2012-12-12
Subject to change without notice
12.1.3
Config master block (block no. 25)
Block no.
25
Block registers
Block words
Master ID
0
Register description
Register name
Block word
Master ID
0
Remark:
In order to request the token, write some number > 0 to the Master ID register.
In order to return the token, write 0x0000 to the Master ID register.
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
Block size
External access
2 Byte
Read
Write
Register size Register description
2 Byte
Master identification
Field bits
Field name
0 ... 15
Token
Field description
0x0000:Token not
assigned.
Other: Token assigned to
some interface.
97