12
Appendix
Note
Block description
Data block name
Operating data block
90
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
This appendix lists the data blocks that are relevant for using the measurement data of
the S3000 expert (section 12.1) and S300 expert (section 12.2).
All data listed in this appendix are volatile, i. e. they are not maintained through power
down.
Only for Compatibility mode: In this appendix, the term Control Area A refers to the active
field set, while Control Area B refers to the active simultaneous field set. The term
Monitoring Area refers to the configured field sets 0 ... (n – 1). Each field set may consist
of one protective field and one or two warning fields. For details on field sets, see the
operating instructions of the S3000/S300.
12.1 Description of the data blocks used in the S3000
12.1.1
Operating data block (block no. 11)
Block no.
11
Block registers
Block words
Operating mode
0
Display data
1 ... 2
Input data
3 ... 4
Output data
5
Monitoring data
6
Configuration counter 7
Device time-on
8 ... 9
Reserved for internal
10 ... 81
use
Register description
Register name
Block word
Operating mode
0
Block size
External access
164 Byte
Read only
Register size Register description
2 Byte
Operating mode of device
4 Byte
Actual display contents
4 Byte
Input data
2 Byte
Output data
2 Byte
Monitoring data
2 Byte
Configuration counter info
4 Byte
Device time-on since last power-up
132 Byte
Reserved
Field bits
Field name
0 ... 3
Device state
4
Device mode
5 ... 7
n/u
Telegram Listing CMS
S3000/S300 Expert
Field description
0: Normal
1: Configuration
2: Lockout
3: System initialization
4: Wait for valid inputs
5: Front screen calibration
6: Boot
7: Production
8: Wait for reset
9: Teach-in
Other: n/u
0: Device is in regular
mode
1: n/u
n/u
8015791/WS20/2012-12-12
Subject to change without notice