ACS 400/450
..5
Description of the unit
.
Keypad and display area
Kg/g
4
min/s
mbar
R134a
Fig. 3
1 Display
2 Control buttons with LED
3 Phase display with LED
4 Unit display with LED
..1
Control buttons
Buttons
Description
For parameter settings
or
V
Select functions or menus
Abort current function and return to
V
(3 sec .)
start screen
E
Confirm selected function or menu
For fault messages only Abort cur-
E
(3 sec .)
rent function Return to start screen
LED
Description
No response to pressing button
Functions or menus can be selected by
pressing button .
Current function or menu is running . No
response to pressing button Only abort
possible .
Robert Bosch GmbH
1
V
R134a
459779/1Pal
3
..
Phase display
Symbol
2
..
Unit display
The unit for the value in the display is indica-
ted using LEDs .
Description
R 134a
Recovery/Recycling phase
V
Vacuum phase
Oil injection phase
R 134a
Filling phase
LED
Description
Phase inactive
Phase active
Phase complete
1 689 979 930 (2005-09-23)
en