1070087088 / 08
|
PST 6xxEx
18
Technical data
18.1
Type‐independent data
Table 12:
Type‐independent technical data: General data
Number of programs
Programming
interfaces
Operating software
(Firmware)
Program memory
Buffer battery
Output of programmed
electrode force
Electrodes
Integrated power
supply unit
Discrete signals
For information on rating and load, refer to section 5.4 from page
294.
for machine applications
for manual gun applications
V24 / RS232;
for programming on location
Ethernet (optional);
for linking of several timers
for machine applications
for manual gun applications
Design
Overvoltage protection
16 inputs
12 outputs
(short‐circuit‐proof)
64;
can be selected via input signals "Program".
8 welding programs and
2 dressing programs;
can be selected via input signals "Program".
Interface X3C, electrically isolated;
Mini‐DIN female connector, 8‐pole
female RJ 45 connector
stored in flash memory;
can be reloaded via software (option) through inter
face
X3C (V24):
via SW "WinBlow"
Ethernet:
via SW "FWUpdate"
RAM; buffered
Lithium battery type AA 3.6 V;
buffers RAM and internal clock with deactivated
power supply for logic.
Battery life approx. 2 years
Analog output (at X2U):
0 to +10 V, max. 20 mA
8 (electrode 0 to 7)
2
Electrode 1: for prog. 1...4
Electrode 2: for prog. 6...9
2‐phase thyristor power supply unit
MOV (metal oxide varistor)
+24 V
; 3 mA
DC
according to EN 61131‐2 Type 3
O00 to O03: +24 V
; max. 1 A
DC
(for solenoid and prelift valves).
O4 to O11 +24 V
; max. 0.1 A
DC
Bosch Rexroth AG
397 / 416