1070087088 / 08
|
PST 6xxEx
8

Commissioning

Switching on the compact weld timer
Dangerous electrical voltage
Possibility of cardiac arrhythmia, burns, shock!
Make sure that unauthorized persons do not work on/in the switch
"
cabinet.
During commissioning, live plant components are accessible at the
open switch cabinet! This reduces the safety of persons and the
plant!
Prerequisite for commissioning is the proper installation and function
• of the entire mechanics of the welding equipment
• of all Emergency-Stop/Emergency-Halt devices
• of the electrical connection including all required sensors
• of the compressed air supply and cooling units.
"
Make sure that the above mentioned prerequisites for commissioning
are met.
Activate the compressed air supply and the cooling units, should this
1.
have to be done manually.
Turn the 24 V supply of the weld timer on.
2.
The red READY LED on the front panel of the timer must now be lit
(power supply is still turned off at this point in time).
Fig. 59: Ready LED
Connect a programming terminal with installed BOS via RS232
3.
(X3C) or Ethernet ("CC Ethernet 100 Mbit" AnyBus module).
The matching data have to be configured in the timer reference of the
BOS for a successful connection setup. Detailed information on this
Bosch Rexroth AG
WARNING
READY LED
331 / 416
Commissioning

Werbung

Kapitel

Inhaltsverzeichnis
loading