400 / 416
Bosch Rexroth AG
Technical data
Primary current meas
1)
uring ranges
operable transformer
nominal power (at 50%
duty cycle, 400 V
AC
and 80% utilization)
Duty cycle
(also refer to load dia
grams, from page 296)
1)
refer to following instruction.
PST 610E L/W
Measuring range 11:
Measuring range 12:
Measuring range 13:
PST 625E L/W
Measuring range 11:
Measuring range 12:
Measuring range 13:
PST 650E W
Measuring range 11:
Measuring range 12:
Measuring range 13:
PST 610E L
non‐ventilated:
with forced cooling:
PST 610E W
PST 625E L
non‐ventilated:
with forced cooling:
PST 625E W
PST 650E W
max. 50% duty cycle)
(independent on possible power unit switched currents; limited by
the integrated 2.2 kOhm field discharge resistor).
When measuring currents, make sure that the minimum primary cur
"
rent never drops below the respective primary current measuring
ranges indicated!
Otherwise, you will have to expect the following effects:
• Decreasing accuracy of current measurement
• Welding schedule is aborted in KSR mode with the fault message
"Schedule aborted, no current".
PST 6xxEx |
1070087088 / 08
18 ... 300 A (default)
63 ... 1100 A
178 ... 2800 A
50 ... 300 A
150 ... 1100 A (default)
450 ... 2800 A
60 ... 380 A
190 ... 1380 A
560 ... 3500 A (default)
68 kVA
95 kVA
95 kVA
106 kVA
141 kVA
155 kVA
565 kVA