Herunterladen Diese Seite drucken

Pepperl+Fuchs LUC-M Serie Betriebsanleitung Seite 36

Ultraschall-füllstandssensor
Vorschau ausblenden Andere Handbücher für LUC-M Serie:

Werbung

LUC-M** mit PROFIBUS PA
Bedienung
Parameter
P+F-Matrix
Standardparameter
Block data
Static revision
Device tag
Strategy
Alert key
Target mode
Mode
Alarm summary
P+F-Parameter
Measured value
V0H0
Tank shape
V0H2
Medium cond.
V0H3
Process cond.
V0H4
Empty calibration
V0H5
Full calibration
V0H6
Output on alarm
V1H0
Outp. echo loss
V1H2
Ramp %span/min
V1H3
Delay time
V1H4
Safety distance
V1H5
In safety dist.
V1H6
Ackn. alarm
V1H7
Measured temp.
V2H0
Max. temp. limit
V2H1
Max. meas. temp.
V2H2
On high temp.
V2H3
Def. temp. sens.
V2H4
Level/ullage
V3H0
Linearisation
V3H1
Customer unit
V3H2
Table no.
V3H3
Input level
V3H4
Input volume
V3H5
Max. scale
V3H6
Diameter vessel
V3H7
Check distance
V4H1
Range of mapping
V4H2
Start mapping
V4H3
Pres. map. dist.
V4H4
Cust. tank map
V4H5
Echo quality
V4H6
Offset
V4H7
Output damping
V4H8
Blocking dist.
V4H9
Instrument_addr.
V5H0
Ident number
V5H1
Set unit to bus
V5H2
Out value
V5H3
Out status
V5H4
Simulation
V5H5
Simulation value
V5H6
2nd cyclic value
V5H7
Select V0H0
V5H8
Display value
V5H9
Display contrast
V6H1
36
P+F-spezifischer Level Transducer Block
Slot
Index
1
130
1
131
1
132
1
133
1
134
1
135
1
136
1
137
1
138
1
140
1
141
1
142
1
143
1
144
1
148
1
150
1
151
1
152
1
153
1
154
1
155
1
158
1
159
1
160
1
161
1
162
1
168
1
169
1
170
1
171
1
172
1
173
1
174
1
175
1
179
1
180
1
181
1
182
1
183
1
184
1
185
1
186
1
187
1
188
1
189
1
190
1
191
1
192
1
193
1
194
1
195
1
196
1
197
1
199
Größe
Typ
[Bytes]
20
DS-32*
2
UNSIGNED16
32
OSTRING
2
UNSIGNED16
1
UNSIGNED8
1
UNSIGNED8
3
DS-37*
8
DS-42*
4
FLOAT
1
UNSIGNED8
1
UNSIGNED8
1
UNSIGNED8
4
FLOAT
4
FLOAT
1
UNSIGNED8
1
UNSIGNED8
4
FLOAT
2
UNSIGNED16
4
FLOAT
1
UNSIGNED8
1
UNSIGNED8
1
UNSIGNED8
1
UNSIGNED8
1
UNSIGNED8
1
UNSIGNED8
2
ENUM
1
UNSIGNED8
1
UNSIGNED8
2
UNSIGNED16
1
UNSIGNED8
4
FLOAT
4
FLOAT
4
FLOAT
4
FLOAT
1
UNSIGNED8
4
FLOAT
1
UNSIGNED8
4
FLOAT
1
UNSIGNED8
1
UNSIGNED8
4
FLOAT
4
FLOAT
4
FLOAT
1
UNSIGNED8
1
UNSIGNED8
1
UNSIGNED8
4
FLOAT
1
UNSIGNED8
1
UNSIGNED8
4
FLOAT
1
UNSIGNED8
1
UNSIGNED8
4
FLOAT
1
UNSIGNED8
Read
Write
Storage Class
X
constant
X
non-vol.
X
X
static
X
X
static
X
X
static
X
X
static
X
dynamic/
non-vol./
static
X
dynamic
X
dynamic
X
X
static
X
X
static
X
X
static
X
X
static
X
X
static
X
X
static
X
X
static
X
X
static
X
X
static
X
X
static
X
X
static
X
X
static
X
X
static
X
X
static
X
X
static
X
X
static
X
X
static
X
X
static
X
X
static
X
X
static
X
X
static
X
X
static
X
X
static
X
X
static
X
X
static
X
X
static
X
X
static
X
X
static
X
dynamic
X
X
static
X
dynamic
X
X
static
X
X
static
X
X
static
X
dynamic
X
X
static
X
X
static
X
dynamic
X
dynamic
X
X
static
X
X
static
X
X
static
X
X
static
X
dynamic
X
X
static

Werbung