Check-In And Alarm Calls - Philips PS6000 Benutzerhandbuch

Ps-micro überwachungsstation
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

PS-Micro control desk LBB 6105/00
1.3 The PS-Micro mobile alarm transmitters
The PS-mobiles are programmed by your system installer to transmit periodic 'check-in' calls to
the control desk within a predefined 'time-limit' confirming that everything is OK. If no response
comes within this 'time-limit' an audible and visible alarm procedure is generated at the control
desk (technical-alarm). An alarm procedure can also be generated manually by the PS-mobile
holder pressing the 'red' alarm button on the PS-mobile, or automatically by the PS-mobile itself
when the 'tear-off ' plug has been removed, or under certain conditions, where prolonged
periods of 'no-movement/not-vertical' have been detected, or when the mobile is in a low
battery state. Each alarm procedure can be assigned a priority 1,2 or 3 programmable by your
system installer. Also included in the control desk are 3-programmable relay contacts, which
depending on how your systems has been set-up, can be used during an alarm procedure - to
activate an auto dialer for example.The auto dialer can be used to call out-side help.The relays
can also be used to set-off an external audible/visual alarm system or even to activate a 3rd-
party paging system.

1.4 Check-in and Alarm calls

The PS-mobiles in your system are capable of transmitting two types of calls to the control desk,
'Check-in' scan calls and 'Alarm' calls.
1.4.1 'CHECK-IN'
scan calls
'Check-in' scan calls are silent
calls sent periodically to the
control desk to inform the
operator about the
operational status of the
mobile - such as 'PRESENT' ,
'ABSENT', or if the mobile's
batteries are low and need
recharging 'LOW BATTERY'.
The period between 'check-
in' calls is defined by your
system installer and varies
depending on the number of
PS-mobiles used in the
system.
If the desk DOES NOT
receive a scan call within this
predefined time, a NO-
SCAN' call alarm will be
raised, indicating to the
operator that this mobile is
technically not OK.
Type
Manual
alarm
LBB 6030
LBB 6031
LBB 6032
LBB 6033
LBB 6034
LBB 6035
Fig. 2 - PS-Micro Mobile alarm transmitter
(LBB 6030 - LBB 6035)
4
Not-vertical/
Tear-off
No-move
alarm
alarm
User Manual
Location
detection

Werbung