2.
START UP PROCEDURE
During start-up, once power is applied to the control desk, the desk performs a 'START-UP' test
procedure, where all its operational functions are checked.
Throughout this
document, the state of
the bi-colour LEDs
(red/green) are
indicated as shown.
START -UP procedure
The display shows the
Software Version (SW) of
your desk and the ROM
CHECKSUM. During this
procedure the bi-colour
LEDs are illuminated, the
green first and then the red.
Display test
After the LED test, the
control desk illuminates all
segments of its display.
Once the 'START-UP' is
complete, the control desk
emits two confirmation
bleeps before entering into
the 'STAND- BY mode (see
3. STAND-BY MODE).
If a problem is encountered
by the control desk during
the 'START-UP' procedure
the control desk enters into
the ERROR HANDLING
mode (see 6 ERROR
HANDLING
PROCEDURES).
PS-Micro control desk LBB 6105/00
Bi-colour LED Indications
G
R
OFF
ON
ON
R
= Red
G =
Green
START UP PROCEDURE
SW VERSION X.XX
G R
G R
G
R
ERROR LOGGING DEVICE
connect logging device
R
Peripheral check
After the 'start-up procedure', the control desk checks
peripheral connected to the system - such as a printer (logging
device) or a DP 6000 paging system. Any errors will be
displayed, and the loudspeaker will emit a 'system-error' bleep
(see 4.7 Audible bleep patterns).
.