7.

LOGGING AND GUARD TOUR

7.1 Introduction
Logging of events is only available if a printer is connected to the RS232 connector of the
control desk.Three logging modes are available (programmed by your system installer):
1.
Logging OFF
2.
Logging of SELECTED events
3.
Logging of ALL events
Table 7.1 gives a list of available logging events (if logging is set to ALL, all items will be logged).
Logging of SELECTED events is intended for the control desk operator to evaluate events when
they happen whereas Logging of ALL events is intended for technicians to evaluate the system.
GUARD TOUR
By enabling a channel to
'guard on' (see 3.2 Channel /
Information) all reported
locations of a PS-mobile are
sent to the printer output
even if logging is set to OFF.
NOTEs:
1. GUARD TOUR is only
applicable for system
including a location
detection facility and a
connected printer.
2. If a printer malfunctions
the control desk will store
up to 32 events (max.) and
print them out only when
the printer becomes
operational again. If more
than 32 events occurred
during this down-time a
message ' Logging device
inactive' will be printed
including the date and time
the device malfunctioned.
Another message will then
be printed 'Logging device
active again' including the
date and time the device
became operational
followed by the stored
events.
PS-Micro control desk LBB 6105/00
Table 7.1 List of logging events
Description
Entering Stand-by mode after Power-up
(cold start)
Receiving a scan call
Receiving an alarm call
Receiving a normal scan-call in the alarm mode
Technical alarm
Receiving a new location from a mobile in non-
alarm status
Receiving a new location from a mobile in alarm
status
Receiving a new location from a mobile in field
coverage test
Pressing any active button in any mode
Alarm acknowledge
Pressing any active button in alarm handling
mode
Changing a system parameter in Set-up mode
When performing a test in test mode
Watchdog 'time-out' (warm start)
Deactivating a mobile
Occurring low priority system error
Pressing any active button in error handling
mode
Outgoing call
Relay activating
23
Eng
Default
YES
NO
YES
YES
YES
NO
YES
YES
NO
YES
YES
NO
NO
YES
YES
YES
YES
NO
YES

Werbung