4.8 Function call – Channe –
4.8.1
Pair ON/OFF Trigger Format (Parameter change)
Receive
Data will be received when [Parameter change Rx] is on and the Device number
of both [Rx CH] and SUB STATUS are matched. The data will be echoed when
[Parameter change ECHO] is on.
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS 0001nnnn 1n
Digital mixer
GROUP ID
00111110 3E
M7CL
MODEL ID
00010001 11
OTHER DATA
DATA
00000000 00
CATEGORY
FUNCTION
01000011 "C"
NAME
01101000 "h"
01101100 "l"
01010000 "P"
01101001 "i"
01110010 "r"
01000011 "C"
01110000 "p"
(ASCII CODE)
MODULE NAME 0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
Source Channel Number H *1)
DATA
0sssssss ss
Source Channel Number L *1)
0sssssss ss
Destination Channel Number H *1)
0ddddddd dd
Destination Channel Number L *1)
0ddddddd dd
End of exclusive
EOX
11110111 F7
4.8.2
Module Name
MODULE NAME
Pair On (with Copy)
"PAIRONCP"
Pair On (with Reset Both)
"PAIRONRS"
Pair Off
"PAIROFF_"
*1) 0:CH1–47:CH48
256:MIX 1– 271:MIX 16
512:MATRIX 1–519:MATRIX 8
4.9
Level Meter Data
4.9.1
Format (Parameter change)
When transmission is enabled by receiving Request for Level Meter, the
corresponding metering data will be sent in every 50 millisecond for 10 seconds.
If metering information is expected to be continuously sent, Request is needed
to be sent in at least every 10 seconds.
Receive
The data will be echoed when [Parameter change ECHO] is ON.
Transmission
When transmission is enabled by receiving Request, the corresponding metering
data will be sent in constant interval for a given period of time (The interval and
time will vary depending on devices). When rebooted or port setting is changed,
the transmission will be disabled.
When [Parameter change ECHO] is on, the message will be sent as it is.
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS 0001nnnn 1n
Digital mixer
GROUP ID
00111110 3E
M7CL
MODEL ID
00010001 11
REMOTE LEVEL METER
DATA
00100001 21
CATEGORY
ADDRESS UL
DATA
0mmmmmmm mm
ADDRESS LU
0mmmmmmm mm
ADDRESS LL
0mmmmmmm mm
Data1
0ddddddd dd
:
:
End of exclusive
EOX
11110111 F7
4.9.2
Format (Parameter request)
Receive
Data will be received when [Parameter change Rx] is on and the Device number
of both [Rx CH] and SUB STATUS are matched. The data will be echoed when
[Parameter change ECHO] is on. the corresponding metering data will be sent
via [Rx CH] in constant interval for a given period of time (The interval and
time will vary depending on devices).
When Address UL = 0x7F is received, all metering data transmission will be
immediately stopped [disabled].
Transmission
When [Parameter change ECHO] is on, the message will be sent as it is.
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS 0011nnnn 3n
Digital mixer
GROUP ID
00111110 3E
M7CL
MODEL ID
00010001 11
REMOTE LEVEL METER
DATA
00100001 21
CATEGORY
ADDRESS UL
DATA
0mmmmmmm mm
ADDRESS LU
0mmmmmmm mm
ADDRESS LL
0mmmmmmm mm
Count H
0ccccccc ch
Count L
0ccccccc cl
End of exclusive
EOX
11110111 F7