In order to save the measuring system input data in the Main_Safety_RTG1
(FB1) block, you must select the block in the Project tree by double-
clicking with the left mouse button. The block opens in the program editor in the
work area.
A MOVE box is inserted in Network 2 from the instructions on the right-hand
side. The MOVE box can be found under Basic instructions in the Move
operationsfolder. For "Position" the tag IN_Pos_Safety is connected at the IN
input and at the OUT1 output the tag ˮIN_DataEncSafetyˮ.Safety_Pos from
the fail-safe data block is connected.
For "Velocity" this process is repeated with the relevant input and output tags.
The programming and modifications are now complete.
Printed in the Federal Republic of Germany
12/17/2020
TR - ECE - TI - DGB - 0340 - 01
TR-Electronic GmbH 2019, All Rights Reserved
Page 115 of 144