Herunterladen Inhalt Inhalt Diese Seite drucken

SICK S3000 Standard Bedienungsanleitung Seite 77

Safety laser scanner
Inhaltsverzeichnis

Werbung

Telegram Listing Standard
S3000/S300
8015792/YY12/2015-02-12
Subject to change without notice
Register name
Block word
Monitoring data
6
Configuration
7
counter
Device time-on
8 ... 9
Reserved for
10 ... 118
internal use
5
Only with S300 Expert in Compatibility mode with resolution configured to 1°.
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
Field bits
Field name
15
Reset required
field D
0 ... 4
Monitoring
case
5 ... 6
n/u
7
Standby
8 ... 12
Control area A
13 ... 15
n/u
0 ... 15
Configuration
counter
0 ... 31
Device time-on
Field description
Reset required by field
evaluation D.
0: No reset required.
1: Reset required.
0 ... 31: Active monitoring
Case
n/u
Device is in standby mode.
0 ... 31:
Standard: Active control
area
5
Enhanced
: Active
protective field
n/u
0: Initial state of connector
plug
Other: Number of
configurations stored in
connector plug so far
Time-on of the device since
power-up [s]
77