Electrical connection of the product

High electrical voltage!
Risk of severe injury or death from electric shock.
Disconnect the relevant system component before performing any maintenance
or repair work.
Secure the system against being unintentionally switched on again.
Damage to the product caused by faulty electrical connection
The product can be damaged.
Electrical connection requires basic mechanical and electrical knowledge.
The product should only be started up by qualifi ed personnel (see page 9).
The voltage supply must comply with the connection data of the lubrication
unit (see "Technical Data" on page 33). Please also observe the manufacturer
documentation listed in Table 1 on page 6.
Malfunctions if electrical connection is faulty
The product can be damaged.
Do not interchange the connection for the actuators and sensor systems.
Connect the lubrication unit to a protection class II power supply or
ground the lubrication unit separately.
• Choose control and sensor elements in accordance with EN ISO 13849.
• Comply with the standard DIN EN 60204 (previously: VDE regulation VDE 0113)
for Germany, or the corresponding regulations in the country of use.
A
A
3
1
Fig. 13:
Plug assignment (view of the connector plugs)
Table 7: Plug assignment connector plug A Operating voltage of lubrication unit
Operating voltage of lubrication unit (plug according to DIN 43650)
Pin
Signal
1
Operating voltage +24 V DC
2
Operating voltage 0 V
3
n.c.
PE
WARNING
NOTICE:
B
4
2
3
1
2
3 842 557 976/2020-08, MIT: LU 2/P-24V-3L, Bosch Rexroth AG