Please note:
• The maximum line length
for hose/tube ⌀ of 4 mm
is 30 m, depending on
the number of lubrication
points.
• Lay the hoses/tubes
without distortion.
• Take component
movements and
thermal expansions into
consideration.
• Observe the dimensions
in Fig. 7.
• Use an appropriate tube
bending device to adjust
the tubing. If tubes are
bent without a bending
device, they may kink!
• Extend tubes only with
the straight bulkhead
fi ttings (C) or the elbow
fi ttings (D).
• Connection and
mounting adapter sets
see chapter 8.5.4 to 8.5.8.
A:
Installation examples
of hose
B:
Installation examples
of tubing
Assemble the
hose/tubing according to
the instructions in Fig. 7.
8.5.3

Installation examples of hose/tubing

A
r
min
!
r
= 15 mm
min
B
r
min
!
r
= 15 mm
min
Fig. 7:
Installation examples of hose/tubing
!
≤ 330 mm
SW3
M
= 2,5 Nm
D
!
≤ 330 mm
!
!
≤ 500 mm
SW10
SW3
M
= 2,5 Nm
D
!
≤ 500 mm
!
D
SW10
M =12 Nm
D
3 842 557 976/2020-08, MIT: LU 2/P-24V-3L, Bosch Rexroth AG
Assembly
25/42
r
min
C
SW10
M =12 Nm
D
r
min
SW12
557 976-05