5.4 Switching on the supply voltage

After the connection and all hardware settings have been carried out, the supply
voltage can be switched on.
The measuring system is initialized first of all and is then in NMT_CS_NOT_ACTIVE
state. In this state the measuring system is passive (listen only), observes the network
traffic, does not send any frames and is waiting for MN commands. The measuring
system can be gradually transferred to NMT_CS_OPERATIONAL state according to the
NMT CN State Machine via the MN:
NMT_CS_PRE_OPERATIONAL_1
With
NMT_CS_PRE_OPERATIONAL_1. In this state the measuring system sends a frame
only if the MN has authorized it to do so by a SoA AsyncInvite command. The
inactive measuring system is requested by the MN over an IdentRequest service
for identification. The measuring system responses with an IdentResponse, a
special type of the ASnd frame. With reception of the IdentResponse the measuring
system is switched actively and can be accessed in the isochronous data
communication phase with a PReq frame.
Initially, in NMT_CS_PRE_OPERATIONAL_1 status only a parameterization via Service
Data Objects is possible. However, it is possible to configure PDOs using SDOs.
NMT_CS_PRE_OPERATIONAL_2
With
NMT_CS_PRE_OPERATIONAL_2. At first the measuring system waits until the
configuration is finished completely, then the node can be accessed with a PReq
frame by the MN. The measuring system responses with a "Dummy PRes", which
contains no process data, the data are marked as invalid. No process data processing
is performed.
NMT_CS_READY_TO_OPERATE
With the NMT command NMTEnableReadyToOperate the measuring system is
switched into NMT_CS_READY_TO_OPERATE and signals its readiness to operation to
the MN. With the reception of a PReq frame by the MN the measuring system is
included into the cyclic data exchange.
Output process data (PReq frames) to the measuring system are already valid, sent
input data (PRes frames) to the MN are marked as invalid. The process data
correspond to the mapping configuration.
NMT_CS_OPERATIONAL
With the NMT state command NMTStartNode the measuring system is switched into
NMT_CS_OPERATIONAL. This is the normal operating state of the measuring system.
Now, active process data exchange between MN and measuring system over PReq
and PRes messages is possible. The process data correspond to the mapping
configuration.
Printed in the Federal Republic of Germany
02/04/2014
a SoA
SoC
or a
SoC
a
frame
TR - ECE - BA - DGB - 0112 - 01
frame the
measuring system is switched
the
measuring
system
into
is
switched
into
 TR-Electronic GmbH 2014, All Rights Reserved