AVENTICS | Bus Coupler AES/Valve Driver AV, CANopen | R412018137–BAL–001–AE
PLC Configuration of the Valve System
5
PLC Configuration of the Valve System
This section requires you to have correctly set the address and baud rate for the bus coupler
and for the bus to be connected to a data termination plug. For a detailed description, see
section 9 "Presettings on the Bus Coupler" on page 99.
For the bus coupler to exchange data from the modular valve system with the PLC, the PLC must be
able to detect the valve system structure. In order to represent the actual configuration of the valve
system's electrical components in the PLC, you can use the configuration software of the PLC
programming system. This process is known as PLC configuration.
Configuration error!
An incorrect valve system configuration can cause malfunctions in and damage to the overall
system.
The configuration may therefore only be carried out by qualified personnel (see section 2.4
"Personnel qualifications" on page 81).
Observe the specifications of the system owner as well as any restrictions resulting from the
overall system.
Observe the documentation of your configuration program.
You may configure the valve system on your computer without the need to connect the unit. The
data can be transferred to the system at a later time on site.
5.1
Readying the PLC configuration keys
Because the electrical components in the valve zone are situated in the base plate and cannot be
identified directly, the PLC configuration keys for the valve zone and the I/O zone are required to
carry out the configuration.
You also need the PLC configuration key when the configuration is carried out in a different location
than that of the valve system.
Note down the PLC configuration key for the individual components in the following order:
– Valve side: The PLC configuration key is printed on the name plate on the right side of the valve
system.
– I/O modules: The PLC configuration key is printed on the top of the modules.
A detailed description of the PLC configuration key can be found in section 12.4 "PLC
configuration key" on page 114.
NOTICE