Display Explanation
overtemperature motor
(NTC/PTC)
motor temperature warning
ballast active
warning ballast
switch off ballast
trailing window exceeded
trailing error with switch off
memory checksum error
internal fault
631 Digital Servo Drive
Ready *
(output X10.5)
off
on
on
on
off
off
* Configuration as stated, refer to Chapter 4:"Operating Modes" - Configuring the OPTO
Inputs and Outputs (X10)
The last error signal will be displayed after restart in EASYRIDER
(History Status Memory, page 7-5).
Diagnostics and Fault Finding
Warning *
Comment
(output
X10.6)
Check overload of the motor/cooling
etc.
*
Check overload of the motor/cooling
etc.
Brake energy is removed
*
Ballast resistance usage is >90%
Ballast resistance overloaded
*
Only in operation mode "position
control"
• optimise parameters
• check mechanics
Only in operation mode "position
control"
• optimise parameters
• check mechanics
• increase trailing window
off
• Try to restart
• Load new parameters
off
• controller fault
Return the unit for repair