Parameterization
To calculate, the parameters steps/rev. and the number of revolutions can be read
on the measuring system nameplate and apply to both scanning units.
The Parameter „Number of revolutions", which results out of the „total measuring range
in steps" and „measuring steps per revolution" has following restriction:
The "number of revolutions" may be a decimal number which can be represented as
fraction in the following area:
1...256000
1...16384
Example 1:
Assumed:
-
-
Derived:
16777216 steps
2048 steps/revolution.
Example 2:
Assumed:
-
-
Derived:
10000000 steps
3600 steps/revolution.
If the resulting number of revolutions cannot be represented in this area, then the
"Measuring range in steps" is corrected to the next smaller value.
The newly calculated total measuring range can be read from the Object 6002h and
is always shorter than the specified measurement length. It may therefore occur that
the total number of steps actually required is not achieved and the measuring system
generates a zero transition before it reaches the maximum mechanical distance.
TR-Electronic GmbH 2021, All Rights Reserved
Page 182 of 204
= Number of revolutions
Measuring range in steps = 16777216
Steps per revolution = 2048
= 8192 revolutions =
Measuring range in steps = 10000000
Steps per revolution = 3600
=
TR-ECE-BA-DGB-0165 v04
8192
1
25000
revolutions =
9
revolutions
=> possible
revolutions
=> possible
Printed in the Federal Republic of Germany
03/06/2024