4.6 Network management, NMT
The network management supports a simplified Boot-Up of the net. With only one
telegram for example all devices can be switched into the Operational condition.
After Power on both scanning units of the measuring system are first in the "Pre-
Operational" condition (2).
(14)
(13)
(12)
Figure 6: Boot-Up mechanism of the network management
State
(1)
(2)
(3),(6)
(4),(7)
(5),(8)
(9),(10),(11)
(12),(13),(14)
Printed in the Federal Republic of Germany
03/06/2024
Power ON or Hardware Reset
(1)
Initialization
(2)
Pre-Operational
(4)
(3)
Operational
Description
At Power on the initialization state is entered autonomously
Initialization finished - enter PRE-OPERATIONAL automatically
Start_Remote_Node --> Operational
Enter_PRE-OPERATIONAL_State --> Pre-Operational
Stop_Remote_Node
Reset_Node
Reset_Communication
TR-ECE-BA-DGB-0165 v04
(7)
(5)
Stopped
(6)
(8)
TR-Electronic GmbH 2021, All Rights Reserved
(11)
(10)
(9)
Page 123 of 204