Start TR_iParameter by means of the start file "TR_iParameter.exe", then open
the template file provided with the measuring system with the menu File -->
Open XML template... (as example here: CDH75M_EPN_001.xml).
Modify the relevant parameters if necessary, and then click on the Generate
CRC switch for the F_iPar_CRC calculation. The result is shown in the field
F_iPar_CRC alternatively as decimal or Hex value.
Each parameter change requires a new F_iPar_CRC calculation, which must then be
taken into account in the projection. If a safety program is already present, it must be
re-generated.
Printed in the Federal Republic of Germany
07/15/2015
TR - ECE - TI - DGB - 0233 - 03