8.13 | The DOLBY® META DATA Instrument
The DOLBY® META DATA instrument is always displayed in
window 3. To set the focus on this instrument (indicated by a
highlighted frame around the window), simply press the instr
key. With the focus on window 3, the DOLBY® META DATA
functions are displayed in the Toolbar (window 1).
The Dolby® E and Dolby® AC-3 decoder is used for the
direct access to coded data streams for analyzing and control-
ling purposes without the need for external decoding.

8.13.1 | Activating the Decoder and changing parameters

If you want to use the Dolby® E and Dolby® AC-3 decoder you have to activate the decoder in the input/Output routing
menus.
Please proceed as follows to access these menus from normal display operation:
1.
Connect the coded signal to the BNC connector marked
with in on the rear side of the units.
Select Menu. The unit changes to menu mode.
2.
Select the edit selected preset button.
3.
Select the local input/Output routing and instrument
4.
settings menu tab. the local routing settings menu is
shown.
Select the Monitoring input routing button.
5.
Check the enable option in the decoder section.
6.
7.
Define the decoder source and type using the correspon-
ding combo boxes.
8.
In order to use decoded signals to be the source of other
inputs, select the decoder option in that input's source
combo box.
SurroundControl 31900/31960 Series
If installed and activated (only included in the D and SD ver-
sions), the Dolby® Meta Data display shows the status of the
Dolby® E or Dolby® AC-3 signal and the status of the de-
coder. It also displays the decoded meta data of the received
bitstream in plain text.
First page of the Dolby® meta
data display
9.
In order to change the assignment of the incoming signals
to the desired instrument channels as displayed, open the
channel combo boxes you want to change and select the
channel with the signal you want to assign to the selected
instrument channel.
10. Proceed until you have made all assignments and approp-
riate changes.
11. Select the save & exit button to store the changes and
leave the menu. The save Preset menu page is displayed.
12. Select a User Preset of your choice to store your settings
in.
13. Select the change name button to edit the preset name.
A keyboard display is shown to enter a new preset name
(6 characters maximum).
14. Select the save & exit button again. All changes are
stored and the unit returns to normal operation.