Causes of faults and remedies

12 Causes of faults and remedies

12.1 Optical displays

Green LED
Off
Flashing
On
© TR-Electronic GmbH 2007, All Rights Reserved
Page 132 of 135
Cause
Voltage supply absent or was
fallen below
Hardware fault,
measuring system defective
No allocation to a master
-
exchanged CAN lines
-
interrupted CAN lines
-
duplicated NODE-ID in the
network
Measuring system ready for
operation
TR - ECE - BA - DGB - 0066 - 04
Remedy
-
Check voltage supply wiring
-
Does the voltage supply is in the permitted
range?
Replace measuring system
-
Adjusted baud rate must agree with the master
baud rate!
-
Check CAN lines
-
Make sure that each NODE-ID is present only
once in the network
-