Parameter Name
No.
AR Trip Mask
1472
0796
AR Trip Mask 2
Defines the trip causes that the AR feature will attempt to automatically reset, followed by an attempt to restart the drive if appropriate.
Refer to Chapter 10 "Trips and Fault Finding" for details of the value corresponding to each trip.
AC30 series Variable Speed Drive
Path
Same as PNO 1469
Setup::Motor Control::Auto Restart
Parameters::Motor Control::Auto
Restart
Parameter Reference
Default
Range
0:01 OVER VOLTAGE
00000000
1:02 UNDER VOLTAGE
2:03 OVER CURRENT
3:04 STACK FAULT
4:05 STACK OVER CURRENT
5:06 CURRENT LIMIT
6:07 MOTOR STALL
7:08 INVERSE TIME
8:09 MOTOR I2T
9:10 LOW SPEED I
10:11 HEATSINK OVERTEMP
11:12 INTERNAL OVERTEMP
12:13 MOTOR OVERTEMP
13:14 EXTERNAL TRIP
14:15 BRAKE SHORT CCT
15:16 BRAKE RESISTOR
16:17 BRAKE SWITCH
17:18 LOCAL CONTROL
18:19 COMMS BREAK
19:20 LINE CONTACTOR
20:21 PHASE FAIL
21:22 VDC RIPPLE
22:23 BASE MODBUS BREAK
23:24 24 V OVERLOAD
24:25 PMAC SPEED ERROR
25:26 OVERSPEED
26:27 STO ACTIVE
27:28 FEEDBACK MISSING
28:29 INTERNAL FAN FAIL
29:30 CURRENT SENSOR
30:31 POWER LOSS STOP
31:32 SPEED SENSOR
0:33 A1
FFFFFFFF
1:34 A2
2:35 A3
3:36 A4
4:37 A5
5:38 A6
6:39 A7
7:40 A8
8:41 SPEED ERROR
9:42 PEERTOPEER OVERRUN
10:43 PHASE CONFIG
11:44 ETHERNET IP BREAK