Connections
:When the pan/tilt head is to be controlled by the AW-RP400 pan/tilt head control panel
for transmitting SDI signals (and the AW-CB400 remote operation panel is used to
control the camera)
Coaxial cable
10BASE-T (equivalent to UTP
category 5) straight cable
(max. 500 m)
Nominal cross section
1.25 mm
AC adapter:
AW-PS300A
• Use the supplied camera cable to connect the unit with the convertible camera
containing the plugged-in SDI card (such as the AW-PB504).
• Use a coaxial cable to connect the SDI card's SDI OUT connector with the unit's SDI
IN connector. Adjust the cable to a length at which the pan/tilt head will move
smoothly.
• Set controller selection switch SW1 to the right side (RP501), and select the
transmission signal selection setting that supports the SDI card.
• Use a 10BASE-T straight cable (UTP category 5) to connect the unit's CONTROL IN
IP/RP connector with the controller's CONTROL OUT TO PAN/TILT HEAD connector.
• Use a coaxial cable to connect the unit's Pr/SDI OUT connector with the colour
monitor's SDI input connector.
• Use the cable supplied with the remote operation panel to connect the controller's
CAMERA CONTROL IN FROM ROP connector with the remote operation panel's
CONTROL OUT TO CONTROL PANEL connector.
• Check that the pan/tilt head and camera can be controlled by the controller.
Camera cable
(supplied)
2
or more
Remote operation
panel:
AW-CB400
Pan/tilt control panel:
AW-RP400
Coaxial cable (BBC
No.PSF1/2M, BELDEN
8281, max. 200 m)
- 35 (E) -
Cable supplied
with AW-CB400
Colour monitor