PRODUCT MAINTENANCE
21.5.
Condensate drain
A wet floor resulting from overflow from the vessel poses a slip hazard.
Regularly empty the condensate collection vessel.
Injury hazard.
Do not connect the condensate drain directly to a waste drain!
Passers-by may be injured.
Switch off the compressor every time before emptying the vessel!
Condensate is automatically separated into the condensate collection tank.
• Monitor the level in the vessel using the markings (depending on the
volume of the vessel), and empty at least once a day.
Injury hazard.
Carefully and slowly open the drain valve. Quickly opening the drain valve is
accompanied by a loud sound and an uncontrollable ejection of the accumulated
condensate.
If necessary, it is possible to drain the air tank using the drain valve (1) from the lower side of the
air tank (Fig. 17).
Switch off the compressor at the mains and reduce the air pressure in the device to a maximum of
1 bar, e.g. by venting air through the connected equipment.
Use a hose to drain with the free end placed in a suitable container and then open the valve to
drain condensate from the tank.
Fig. 17: Condensate drain
03/2023
Fig. 16: Check of the condensate collection vessel
41
NP-DK50 PLUS, 2V-ADS-A-3_03-2023