TECHNICAL DATA
Working pressure 6 – 8 bar
Nominal voltage, Frequency
Capacity at 6 bar (FAD)
b)
Working pressure
Rated current
Motor power
Air tank volume
Air quality - filtration
Maximum operating pressure of safety valve
Noise level at 5 bar (LpA)
Operating mode
PDP drying performance at 7 bar
Time to fill air tank from 0 to 7 bar
Dimensions (net)
w x d x h
c)
Net weight
a)
Specify the compressor version when ordering
b)
Consult any other range of pressure with the supplier
c)
Weight is indicative and only applies to the product without accessories
d)
In order to maintain the declared dewpoint, the maximum continuous air cosumption of the connected
device shall not exceed 78 l/min.
Dependence of compressor output on working pressure
03/2023
a)
17
DK50 2V/M
V, Hz
230, 50
d)
l/min
135
6.0 – 8.0
bar
A
8.7
kW
1.2
l
25
m
-
bar
11.0
≤ 69
dB
%
S3-70%
-20
°C
s
80
mm
460x565x710
kg
61
NP-DK50 PLUS, 2V-ADS-A-3_03-2023
DK50 2V S/M
230, 50
d)
135
6.0 – 8.0
8.9
1.2
25
-
11.0
≤ 55
S3-70%
-20
80
560x690x875
99