11. PNEUMATIC CONNECTION

11.1.
Connecting to the compressed air outlet
• Connect the pressure hose (2) to the compressed air outlet (1) of the compressor.
• Route the hose to the compressed air manifold or directly to the appliance.
• Secure the pressure hose in the clamp (3) (Fig. 5).
• Route the pressure hose through the opening in the rear wall of the cabinet for cabinet-
mounted compressors (Fig. 7).
11.2.
Connecting the cabinet pressure gauge to the compressor
• Remove the plug (1) from the threads (2) on the
pneumatic block of the compressor.
• Connect the cabinet pressure gauge hose to the
threaded fitting.
11.3.
Connecting the condensate container and the air outlet from the pressure switch
• Connect the condensate collection tank (1) to the condensate outlet on the dryer using a hose,
and then connect the hose (2) from the pressure switch to the collection tank (Fig. 7). It is
necessary to fit the supplied reducer to the inlet of the collecting vessel for the hose (2).
• With the compressor in the cabinet, route the hose through the hole in the back wall of the
cabinet and connect it to the collection tank. Mount the condensate collection tank to the side
panel or to the back panel of the cabinet (Fig. 7).
NP-DK50 PLUS, 2V-ADS-A-3_03-2023
Fig. 5: Connecting to the compressed air outlet
Fig. 6: Connecting the cabinet pressure gauge to the compressor
22