17.5. Condensate drain

Compressors
Open the drain valve carefully and slowly. If the drain valve is opened too much,
it is accompanied by high noise level and uncontrolled jet of the accumulated
condensate
Risk of slipping on a wet floor in case of the collecting vessel overflow.
During regular operation, it is recommended to drain
condensate from the pressure tank.
Switch off the compressor from the mains and
decrease air pressure in the device to max. 1
bar, e.g. by releasing air through the
connected device
Install the hose with condensate drain valve
into the prepared bottle and drain condensate
from the tank by opening the drain valve (1)
Compressors can be equipped with Automatic condensate drain (AOK), which provides draining of
condensate from the air tank without the need of operator action (see chapter Annex).
Compressors with air dryer
Condensate from compressors with air dryers is
automatically drained into the condensate collection
vessel.
Monitor the level in the vessel using the 1 l or
2 l markings (depending on the volume of the
vessel), and empty at least once a day
Before the following checks it is required:
Compressor variants with cabinet DK50 PLUS S, DK50 PLUS S/M, DK50 2V/S, DK50 2V
S/M – unlock the door lock and open the cabinet door.
NP-DK50 PLUS, 2V-A-3_02-2020-MD
Fig. 15: Condensate drain from the pressure tank
Fig. 16: Check of condensate collection vessel
40
PRODUCT MAINTENANCE
02/2020