THE FOLLOWING IS REQUIRED BEFORE ANY FOLLOW-UP CHECKS
Compressors with cabinet - release the door lock and open the cabinet door.
Safety valve check
(Fig. 16)
When the compressor is operated for the first time, make sure
that the safety valve is working properly. Turn the screw (2)
on the safety valve (1) several rotations to the left until the
safety valve releases air. Let the safety valve vent for only a
few seconds. Turn the screw (2) to the right until it seats,
closing the valve.
Never use the safety valve to vent air pressure in the air tank. It could damage the
safety valve. The valve is set to the maximum permitted pressure by the
manufacturer. Adjustments are not permitted!
WARNING! COMPRESSED AIR IS DANGEROUS BECAUSE OF THE RISK OF
DAMAGE TO THE EYES! RISK OF DAMAGE TO THE EYES.
Replacing the inlet filter and pre-filter
(Fig. 17)
The inlet filter is located inside the compressor crankcase cover.
Inlet filter replacement:
• Pull out the rubber plug by hand (2).
• Remove the used filter (1).
• Insert a new filter and replace the
rubber plug.
Pre-filter replacement:
• Pull out the pre-filter by hand (3).
Replace the element and re-insert.
DK50 PLUS
Fig. 17
NP-DK50 PLUS, 2V-14_07-2021-MD
DK50 2V
1
2
- 42 -
DK50 PLUS, DK50 2V
:
1
2
Fig. 16