Condensate drain
Compressors
Draining the condensate from the pressure vessel is recommended during regular operation.
Switch off the compressor at the mains. Reduce air pressure in the device to max. 1 bar by
releasing air via a connected device.
Release the drain valve from the clips on the compressor base. Place the open end of the hose
into a suitable container and open the drain valve (1) to drain off the condensate from the
container.
In cabinet mounted compressor models, the condensate may be drained outside of the cabinet.
Fig.14
Carefully and slowly open the drain valve. Quickly opening the drain valve is
accompanied by a loud sound and uncontrollable stream of accumulated
condensate.
Compressors without a dryer may be equipped with the
Automatic Condensate Drain to allow the condensate to
drain without operator intervention (see chap. 8.2.).
Compressors with air dryer (Fig. 15)
Condensate
from
automatically drained into a collecting bottle. The bottle must
be drained regularly.
Monitor the level in the vessel using the 1 l or 2 l markings (depending on the
volume of the vessel), and empty at least once a day. The vessel may overflow if
the condensate is not drained out of the vessel at the defined interval.
Risk of slipping on a wet floor in case of the collecting vessel overflow.