PC Connection
Danger! High Voltage!
Even when the PC is switched off, parts in the PC are still live.
Switch off the PC before you open it and pull out the power connector.
Sensitive electronics
Suprasetter and PC must be switched off. Connect cables when machine is
deenergized only.
Fig. 95 PC inside
Fig. 96 PC rear
Suprasetter 145/162/190 – Installation
DANGER
NOTICE
Open the PC.
Insert PCB GPIB with the two ports for LVDS and
GBit (Fig. 95/1) and the Ethernet board for connec-
tion of the GUI (Fig. 95/2). The two PCBs are in the
accessories kit located at the bottom of the plate
loader when shipped. .
Close the PC again.
Plug in the GBit and GUI cables (Fig. 96/1) at the
rear of the PC and route them to the electronics
box of the imaging unit.
Installation