DPV1
Slot
Index
3
87
3
87
3
91
3
92
3
93
3
94
3
95
3
96
3
97
3
98
ClipX
No of
Data
bytes
type
1
UINT8
1
UINT8
2
UINT16
2
UINT16
2
INT16
2
UINT16
1
UINT8
0
—
4
UINT32
0
—
A04643_04_X00_03 HBM: public
R/W
Description
RW
TEDS usage
0: Ignore
1: If available
2: Required
RW
TEDS search during
parameter set
change
0: No
1: Yes
RO
Get active parameter
set
WO
Activate a certain
parameter set
WO
Command: Save
parameter set to file
RW
Boot parameter set
RW
Digital input switch
mode
0: Off
1: Digital IN 0
2: Digital IN 0+1
WO
Command: Activate
factory default
RO
CRC of currently
used parameters
WO
Command: Re-cal-
culate CRC of cur-
rently used
parameters
Betrieb über Feldbus
ClipX object
directory
Index
index
0x4300
0x4300
0x4270
0x4270
0x4270
0x4270
0x4270
0x4270
0x4270
0x4270
Sub-
2
3
1
2
3
4
5
6
8
9
149