en
68 | EPS 205 | Maintenance
4
6 ±0,5 Nm
Fig. 48:
Replacing the strainer
1 Hose fitting
2 Strainer
3 Banjo bolts
4 Strainer bracket
5 Hose assemblies
6. Remove hose assemblies (fig. 48, item 5) from the
hose fittings (fig. 48, item 1).
7. Remove both banjo bolts (fig. 48, item 3) at the
strainer brackets (fig. 48, item 4) of the changeover
valve (fig 47, item 4).
8. Clamp the strainer bracket in a vice.
9. Remove both hose fittings from the strainer bracket
using an open-ended wrench.
10. Remove strainer (fig. 48, item 2) from both strainer
brackets and locate the new strainers in the strainer
brackets in their correct position.
11. Tighten the hose fittings (hose fitting with seal)
to the strainer brackets using a torque wrench
(30 Nm ±2 Nm).
12. Remove the strainer bracket from the vice.
13. Secure strainer bracket to changeover valve using
banjo bolts with seals using a torque wrench
(6 Nm ±0.5 Nm).
14. Slide the hose assemblies onto the hose fittings and
secure them.
15. Screw the ground cable to the housing cover.
16. Secure the housing cover using fastening screws
(8x).
"
Strainers are replaced.
|
1 689 989 185
2018-03-24
30 ±2 Nm
5
2
6 ±0,5 Nm
3
6.3
Spare and wearing parts
1
Designation
Connection adapter with
adapter nut M12
and
<)
adapter nut M14
<)
Spare parts set for connection adapter with
O-ring (2x) and support ring (2x)
Sealing plug
<)
Inlet connector
12 O-rings 9.5 x 2
<)
Inlet filter
Adapter for check valve
Spare parts set for inlet filter with flat
sealing ring, filter element and O-ring
(6x each)
<)
Knurled nut 9 mm
<)
Knurled nut 7 mm
<)
Hose
1.5 m
<)
(for draining test oil tank)
Flushing drain
<)
Hose (injection)
<)
Hose (return)
<)
Hose (return)
<)
Pen
Adapter cable set for injector test
(1 684 465 841 and 1 684 465 842)
Intake filter for test oil tank (3x)
Flowmeter pipe filter
<)
Toothed belt
<)
Guard
Hose
(CRI Piezo return inlet)
<)
Hose
(CRI Piezo return outlet)
<)
DVD drive
Adapter cable
for CRI Piezo
<)
Adapter cable
for CRI Piezo
<)
Adapter cable
for CRIN
<)
Adapter cable
for CRI
<)
Adapter cable
for CRI
<)
O-Ring 12 x 2
for injection chamber
<)
O-Ring 9 x 3
for injection chamber
<)
O-Ring 7 x 4
for injection chamber
<)
Strainer
(2x) for changeover valve
<)
High-pressure hose assembly
Wearing parts
<)
Customer service performs maintenance and exchanges.
1)
Order number
1 687 023 641
1 680 210 150
1 683 370 038
1 683 386 166
1 680 210 143
1 687 434 067
1 683 350 904
1 687 001 974
1 683 373 086
1 683 373 087
1 680 712 283
1 680 712 293
1 680 712 362
1 680 712 287
1 680 712 360
1 683 083 004
1 687 010 171
<)
1 685 431 015
<)
1 687 434 051
1 684 736 022
1 685 510 238
1 680 703 078
1 680 703 079
1 687 023 846
1 684 465 669
1 684 465 671
1 684 465 843
1 684 465 841
1 684 465 842
1 680 210 123
1 680 210 132
1 680 210 124
1 680 002 020
1 687 010 369
<)
Robert Bosch GmbH
1)