Processor And Heat Sink; Removing A Processor And Heat Sink Module - Dell EMC PowerEdge R740xd2 Installations- Und Servicehandbuch

Vorschau ausblenden Andere Handbücher für EMC PowerEdge R740xd2:
Inhaltsverzeichnis

Werbung

ANMERKUNG:
The memory module socket has an alignment notch that enables you to install the memory module in
the socket in only one orientation.
3. Press the memory module with your thumbs until the ejectors firmly click into place.
VORSICHT:
To prevent damage to the memory module or the memory module socket during installation, do not bend
or flex the memory module. You must insert both ends of the memory module simultaneously.
VORSICHT:
Do not apply pressure at the center of the memory module; apply pressure at both ends of the memory
module evenly.
Abbildung 74. Installing a memory module
Nächste Schritte
1.
Install the air
shroud.
2. Install
the system
cover.
3. Place the system into the rack. For more information, see the Schieneninstallationshandbuch unter
poweredgemanuals.
4.
Open the drive
bays, install
5. Install the
power supply
6. Follow the procedure listed in
7. To verify if the memory module has been installed properly, press F2 and navigate to System Setup Main Menu > System BIOS >
Memory Settings. In the Memory Settings screen, the System Memory Size must reflect the updated capacity of the installed
memory.
8. If the value is incorrect, one or more of the memory modules may not be installed properly. Ensure that the memory module is firmly
seated in the memory module socket.
9. Run the system memory test in system diagnostics.

Processor and heat sink

Removing a processor and heat sink module

Voraussetzungen
WARNUNG:
The heat sink may remain hot to touch for some time after the system is powered down. Allow the heat sink
to cool before removing it.
1. Follow the safety guidelines listed in
2. Power off the system and all attached peripherals.
3. Disconnect the system from the electrical outlet, and disconnect the peripherals.
4.
Open the drive
bays, remove
98
Installing and removing system components
all
drives, and then
close the drive bays.
units.
After working inside your
Safety
instructions.
all
drives, and then
close the drive bays.
system.