Encoder Slot 2
Parameters::System Board::Encoder Slot 2
This feature allows you to setup and monitor the operation of the encoder attached to slot 2 of the system board.
Parameter Name
No.
1671
Encoder Lines
The number of lines per encoder revolution
1672
Encoder Invert
Reverses the encoder direction if TRUE.
1673
Encoder Type
Normally the encoder will be quadrature. Exceptionally, eg if a proximity sensor or other pulse train is used, it needs to be clock /
direction.
1674
High Input Threshold
Changes the threshold level for the encoder pulses between 1.8 V and 6.5 V typical. For encoders powered from 5 V the low theshold
should be used. For other supply voltages the high threshold will provide greater noise immunity.
1675
Encoder Speed
The speed measured by the encoder, in revolutions per minute.
1676
Encoder Count Reset
Resets the encoder count.
AC30 series Variable Speed Drive
Path
Setup::Inputs and Outputs::SB Encoder
Slot2
Parameters::System Board::Encoder
Slot 2
Same as PNO 1671
Same as PNO 1671
Same as PNO 1671
Parameters::System Board::Encoder
Slot 2
Same as PNO 1671
Parameter Reference
Default
Range
2048
1 to 100000
FALSE
0
0:QUADRATURE
1:CLOCK/DIRECTION
FALSE
FALSE
D-57
Units
Writable
STOPPED
STOPPED
STOPPED
STOPPED
RPM
NEVER
ALWAYS