Configure, (Phase Control)
Parameters::Phase Control::Configure
Used to select Master and slave encoder source.
Gives a diagnostics of the configuration related to the encoder selection for the motor control, the Master ( Reference ) and the Slave.
Parameter Name
No.
1745
Master Position Src
Specifies the encoder to be used as the Master, (Reference) input :
MAIN SPEED FEEDBACK
SYSTEM BOARD SLOT 1
SYSTEM BOARD SLOT 2
NONE
: no Master selected
1744
Slave Position Src
Specifies the encoder to be used as the Slave input. Normally this will be the same as the speed feedback.
SAME AS MOTOT FBK : the Slave encoder is the encoder used as the motor feedback.
MAIN SPEED FEEDBACK : corresponds to the I/O feedback option
SYSTEM BOARD SLOT 1 : corresponds to the Slot 1 of the system board option
SYSTEM BOARD SLOT 2 : corresponds to the Slot 2 of the system board option
By default, the value
If the Slave and the Motor Feedback are the same encoder, use
occur : Motor speed feedback and position feedback ( slave ) cannot be the same.
1749
Setup Successful
The configuration of the master, slave and Speed loop encoders is correct
AC30 series Variable Speed Drive
Path
Parameters::Phase Control::Configure
: corresponds to the I/O feedback option
: corresponds to the Slot 1 of the system board option
: corresponds to the Slot 2 of the system board option
Parameters::Phase Control::Configure
is selected.
SAME AS MOTOT FBK
Parameters::Phase Control::Configure
Parameter Reference
Default
Range
3
0:MAIN SPD FEEDBACK
1:SYSTEM BOARD SLOT 1
2:SYSTEM BOARD SLOT 2
3:NONE
0:SAME AS MOTOR FBK
0
1:MAIN SPD FEEDBACK
2:SYSTEM BOARD SLOT 1
3:SYSTEM BOARD SLOT 2
, otherwise, an error 301 or 302 or 303 will
SAME AS MOTOT FBK
D-33
Units
Writable
STOPPED
STOPPED
NEVER