3. The LCD display shows: 101: Comms=OFF
4. Via the keypad, select from the following items
and press:
Comms=OFF
0
The alarm centre does not use any
communication devices.
Comms=Single
Single report. The alarm centre reports
to a programmed telephone number
(command 115) with an access number
1
(command 117). The alarm centre dials
the number and attempts to establish a
connection to the central station (max.
15 attempts).
Comms=ALT
The alarm centre dials one of two
programmed numbers and attempts to
establish a connection to the central
station. If the attempt is unsuccessful
2
then the alarm centre dials the second
of the two numbers (max 15 attempts
for each number). If the connection is
successful and the alarm is confirmed
then the connection is subsequently
closed.
Comms=Dual
Dual Report. As in item 2, 2 numbers
are dialled and an attempt is made to
establish a connection to the central
3
stations. However, both central stations
must have successfully confirmed the
alarm (max. 15 attempts until both have
successfully confirmed).
5. Confirm your input. On the control unit, enter:
.
6. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
103 Format Report
Proceed as follows to change the property of the format
report:
1. On the control unit, enter:
2. The LCD display shows: 126:Format=FF
3. Via the keypad, select from the following items
and press:
Format=FF
0
Fast format
Format=CID
1
Contact ID
Format=SIAI1
2
Scancom SIA Level I
Format=SIA2
3
Scancom SIA Level 2 (transmits no
time+date)
Format=SIA3
4
Scancom SIA Level 3
Format=XSIS3
5
Extended Scancom SIA Level 3
Format=Hbeep
Home „beep" No particular format. The
6
alarm centre dials a number and
transmits a „beep" See command 186.
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
71
103
UK