alarm and the external siren are
activated.
B=Full
On alarm, the control units, the internal
2
signalling, the external sirens and the
telephone dialler are activated.
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
065 Exit delay time internal B
To change the property of the exit delay time for internal
active B:
1. On the control unit, enter:
2. The LCD display shows: 065: Exit B=20
3. Via the keypad, select from the following items
and press:
Exit B=10
1
Exit delay time for internal active B is 10
seconds.
Exit B=20
2
Exit delay time for internal active B is 20
seconds.
Exit B=30
3
Exit delay time for internal active B is 30
seconds.
Exit B=45
4
Exit delay time for internal active B is 45
seconds.
Exit B=60
5
Exit delay time for internal active B is 60
seconds.
Exit B=120
6
Exit delay time for internal active B is
120 seconds.
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
065
61
066 Forbikobler partitions
To change this property (only possible in partitioned
systems):
1. On the control unit, enter:
2. The LCD display shows: 066:Forbi 1 abcd
3. Via the keypad, select from the following items
and press:
A
Assign control unit of partition A.
B
Assign control unit of partition B.
C
Assign control unit of partition C.
Assign control unit of partition D.
D
4. Confirm your input. On the control unit, enter:
.
5. Repeat these steps for the remaining Forbikobler
control units.
6. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
067 Forbikobler correct
Proceed as follows to change the property of the
Forbikobler correct:
1. On the control unit, enter:
2. The LCD display shows: 067:Frb=Non-Appr
3. Via the keypad, select from the following items
and press:
Frb=Non-Appr
0
Proximity code key and user codes are
allowed for the access.
Frb=Approved
1
Only user codes are allowed for the
access (correct).
4. Confirm your input. On the control unit, enter:
.
066
067