058 BVVO Sabotage reset
Proceed as follows to change the property of the BVVO
sabotage reset:
1. On the control unit, enter:
2. The LCD display shows: 058: BVVOtamp OFF
3. Via the keypad, select from the following items
and press:
BVVOtamp OFF
The user can carry out a reset in case
0
of tampering when the alarm centre is
deactivated.
BVVOtamp OFF
If the alarm centre is deactivated in
1
case of tampering then an installer
reset is required.
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
059 Sabotage siren
Proceed as follows to change the property of the sabotage
siren:
1. On the control unit, enter:
2. The LCD display shows: 059: BellTamp=NEG
3. Via the keypad, select from the following items
and press:
BellTamp=NEG
0
There is no resistor in the sabotage
loop (NC)
BellTamp=EOL
1
The sabotage loop is protected by a
2.2kOhm resistor (EOL)
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
058
059
59
060 Entry/exit behaviour on internal active
(B)
To change the zone property of the entry/exit zone at
internal active (B):
1. On the control unit, enter:
2. The LCD display shows: 060: B=FE =FE
3. Via the keypad, select from the following items
and press:
B=FE =FE
A zone programmed as entry/exit keeps
this property even for internal activation
0
and thus starts the entry delay time
when the zone triggers and during
active internal activation.
B=FE = NA
A zone programmed as entry/exit
changes its zone property during
1
internal activation to immediate and
triggers an alarm if the zone triggers
and during active internal activation.
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
061 Entry to follow behaviour on internal
active (B)
To change the zone property for internal active (B):
1. On the control unit, enter:
2. The LCD display shows: 061: B=ER =ER
3. Via the keypad, select from the following items
and press:
B=ER =ER
A zone programmed as entry to follow
0
keeps this property even during internal
activation and permits entry to this zone
during the entry delay period.
B=ER = FE
1
A zone programmed as entry to follow
060
061