Herunterladen Inhalt Inhalt Diese Seite drucken

Abus Terxon MX Installationsanleitung Seite 172

Vorschau ausblenden Andere Handbücher für Terxon MX:
Inhaltsverzeichnis

Werbung

15
UK
16
17
In a partitioned system
18
19
20
21
22
23
24
25
Set Comp1
This output is active for 10 seconds
after the system has been activated.
Unset Comp1
This output is active for 10 seconds
after the system has been deactivated
or after an alarm has been deactivated.
System Alarm
This output is activated when the alarm
centre has detected an alarm.
Bell Partition A
This output is active when an alarm has
been detected in partition A.
Bell Partition B
This output is active when an alarm has
been detected in partition B.
Bell Partition C
This output is active when an alarm has
been detected in partition C.
Bell Partition D
This output is active when an alarm has
been detected in partition D.
Strobe Set Partition A
This output is active for 10 seconds
after partition A has been activated.
Strobe Set Partition B
This output is active for 10 seconds
after partition B has been activated.
Strobe Set Partition C
This output is active for 10 seconds
after partition C has been activated.
Strobe Set Partition D
This output is active for 10 seconds
after partition D has been activated.
Set 1
This output is activated for a definable
time period (command 170) if the alarm
26
centre is activated completely (A) or
internally (B), (C) or (D) (command
171).
Set 2
This output is activated for a definable
time period (command 170) if the alarm
27
centre is activated completely (A) or
internally (B), (C) or (D) (command
171).
Set 3
This output is activated for a definable
time period (command 170) if the alarm
28
centre is activated completely (A) or
internally (B), (C) or (D) (command
171).
Set 4
This output is activated for a definable
time period (command 170) if the alarm
centre is activated completely (A) or
29
internally (B), (C) or (D) (command
171).
The output is also activated if a fire or
panic alarm is triggered.
Unset 1
This output is activated for a definable
time period (command 170) if the alarm
30
centre is deactivated completely (A) or
internally (B), (C) or (D) (command
171).
Unset 2
This output is activated for a definable
time period (command 170) if the alarm
31
centre is deactivated completely (A) or
internally (B), (C) or (D) (command
171).
Unset 3
This output is activated for a definable
time period (command 170) if the alarm
32
centre is deactivated completely (A) or
internally (B), (C) or (D) (command
171).
68

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis