Parameterization

7.4.3.5 Attribute 12, Direction Counting Toggle

Direction Counting Toggle sets the counting direction of the measuring
system.
BOOL
Access Value Description
Set/Get
Connection path, Packed EPATH with 8 bit class
0x20
Logical Type
= Class
This attribute only takes effect after executing service code 0x16 save or attribute 112
Accept Parameter.

7.4.3.6 Attribute 15, Position Format

Position Format sets the output format of the position value (attribute 10) it is
permanently set to „steps".
ENGUNIT
Value
0x1001
Connection path, Packed EPATH with 8 bit class
0x20
Logical Type
= Class
This attribute only takes effect after executing service code 0x16 save or attribute 112
Accept Parameter.
 TR-Electronic GmbH 2013, All Rights Reserved
Page 128 of 175
0
Position increasing clockwise (view onto the shaft)
1
Position decreasing clockwise (view onto the shaft)
0x23
0x24
Logical Type
Class #23
= Instance
Unit
steps [stp]
0x23
0x24
Logical Type
Class #23
= Instance
TR-ECE-BA-DGB-0102 v10
0x01
0x30
Logical Type
Instance #1
=Attr.-ID
0x01
0x30
Logical Type
Instance #1
=Attr.-ID
Printed in the Federal Republic of Germany
Default
X
0x0C
Attr.-ID #12
0x0F
Attr.-ID #15