Herunterladen Inhalt Inhalt Diese Seite drucken

System Commands - Balluff BMP 01 P A P-Serie Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
BMP 01- _P _ _ _  _ _A- _ _ _ _ - _ _ -P _ _ /P _ _ -S4/P _ _ -S75
Magnetic field positioning system
8
IO-Link interface (continued)
8.4

System commands

Different commands have been implemented in the BMP
which can be reached via the parameter System
Command on Index 2, Subindex 0. If a system command
is transferred to the BMP, the command triggers the
desired action if permitted in the current application state.
Command
Name
0x01 (1)
ParamUploadStart
0x02 (2)
ParamUploadEnd
0x03 (3)
ParamDownloadStart
0x04 (4)
ParamDownloadEnd
0x05 (5)
ParamDownloadStore
0x41 (65)
SP1 Single Value Teach
0x42 (66)
SP2 Single Value Teach
0x4E (78)
Teach Reset
0x80 (128)
Device Reset
0x82 (130)
Restore Factory Settings
0xA5 (165)
Reset Maintenance
0xE0 (224)
Teach Preset
0xE1 (225)
Teach Measurement
Range Lower Limit
0xE2 (226)
Teach Measurement
Range Upper Limit
Tab. 8-5:
System commands Index 2, Subindex 0
22
english
Description
Starts parameter upload.
Ends parameter upload.
Starts parameter download.
Ends parameter download.
Finishes parameter setting and starts data storage.
Saves the currently measured position as Setpoint 1).
Saves the currently measured position as Setpoint 2).
Deletes the SP1 and SP2 values of all SSCs.
Reinitializes all device components.
Resets all configurations to their factory settings.
Resets all operating parameters.
Calculates and saves the PDV offset, sets the current output value to the
preset value.
Teaches the current position as the lower limit of the measurement range.
Teaches the current position as the upper limit of the measurement range.

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Bmp 01 p a p s4-serieBmp 01 p a p s75-serie

Inhaltsverzeichnis